Only the circulation pump will run above 39☏ (4☌). Spas with ACC control systems Error message Heater not detected during configuration. The pump configured for circulation and heating is not the one detected during teach-in.Ĭonnection error or inconsitent connection with the detection made during learning. If the spa does not restart, turn it off and contact a specialist. The temperature detected by the Hi-limit sensor is outside the possible temperature range: below 0☌ (32☏) or above 48☌ (118☏). The temperature detected by the temperature sensor is outside the possible temperature range: below 0☌ (32☏) or above 48☌ (118☏). Try restarting the spa or letting the spa cool down. Hi-limit sensor may be defective, or the spa is overheating. It could be a setting error or the flow sensor or pressure switch could be defective. No flow detection when there should be one. Spas with Astrel, Gecko SSPA and MSPA control systemsįlow detection when there shouldn't be any. If it displays HOt, HOT-CALL SVC: contact us. * Even when the spa has stopped, some functions may start up again if protection against freezing is necessary The DIP switch numbers and the configuration setting values displayed on the topside panel following the "CFE" message are in conflict with each other.Ĭontact a specialist to check the switch numbers and the values in the configuration settings, and correct as needed to match the equipment in the spa system. There is a "Configuration Error" (CFE) in the DIP switches or configuration settings. This indicates a possible problem with the motherboard. The real time clock keeps the current time of day. The "Real Time Clock" (rtC) cannot be read. If the problem continues, contact a specialist. Try turning the power off and back on again. It stores all the programming information, such as filter cycles, set temperatures, user settings and configuration settings. The "Persistent" (PSt) memory cannot be read. Turn off the spa and contact a specialist. Once it does, the heater and blowers stay on for another four minutes until the spa functions normally againĪ pump may be stuck on. Temperature is below 45☏ (7☌) - risk of ice*.Īll equipment is automatically switched on until the temperature reaches 45☏ (7☌). Temperature has dropped 50☏ (10☌) below the required temperature The spa will not turn back on automatically. The spa turns off.įollow necessary instructions for the "dr" message. Message appears after the 3rd "dr" message. If the water levels are normal, make sure that all the pumps are on. There may be an air bubble in the heating circuit or a lack of flow in the heater. The message should restart in the following 15 minutes. The heater is off but other funtions are still on. Message appears after the 5th "HL" message in 24 hours.Ĭontinuously insufficient water flow. The Hi-limit overheating sensor may be defective This may be temporary of one of the sensors may be defective If the problem continues, contact a specialist (this message may appear temporarily if the spa overheats).Ī temperature difference was detected between the two M7 sensors. if the spa does not restart, cut off the power supply and contact a specialist. Once the heater has cooled, restart the spa by pressing any button. Remove the cover and let the water cool down. Heater overheating - the spa has stopped* and the temperature detected in the heater is higher than 48☌. If it does not restart, cut off the power supply and contact a specialist. Once the water reaches 106☏ (41.7☌), the spa should restart automatically. Spa overheating - the spa has stopped* and the temperature detected in the spa is higher than 113☏ (43.5☌). Temperature should appear after the pump has been on for two minutes.
#COLEMAN SALUSPA ERROR CODES MANUAL#
If you can't find the message below, feel free to refer to the user manual or to contact us. All Balboa systems use the same error codes on their keypads.